Chat Live

OBTURATING INTRODUCER FOR NASAL ENDOTRACHEAL TUBES

This novel innovation offers the benefits of a simpler, safer and more predictable nasal endotracheal intubation method.

 

Evidence based studies have shown that the use of an obturating introducer for nasal intubation significantly
reduces the risk of incidence and severity of epistaxis to the same, or less than, the incidence when using a red
rubber catheter. It also reduced incidence of nasopharyngeal soft tissue damage and nasal pain post intubation.

The proximal end of the intubation device is manufactured to connect with anendotracheal tube with a posterior facing
bevel that allows for easier placement of the endotracheal tube in the trachea without the need for rotation.

Gallery

Additional Information

  • Suspected base of skull fractures
  • Bleeding diathesis

Our obturating introducer for nasal endotracheal tubes is presented as a pack containing:

  • A nasal endotracheal tube with a posterior facing bevel
  • An introducer that mates with the endotracheal tube.

Obturating Introducer – Flexible reinforced

Obturating Introducer – PVC RAE

Our obturating introducer for nasal endotracheal tubes is presented as a pack containing:

  • The appropriate sized endotracheal tube is selected for the patient.
  • The endotracheal tube is mated with the introducer.
  • The most patent nostril is selected and the introducer is lubricated and passed along the floor of the nostril and nasopharynx until the distal end of the introducer can be visualized in the mouth using a laryngoscope.
  • The distal end of the introducer is grasped with Magill’s forceps and delivered through the mouth. By pushing on the endotracheal tube distal to the nostrils and pulling the introducer through the mouth the distal end of the endotracheal tube is delivered into the oropharynx .The introducer is uncoupled from the endotracheal tube and removed. The endotracheal tube can then be passed into the trachea through using a laryngoscope.

SIZES – INTERNAL DIAMETER OF TUBE:
REINFORCED FLEXIBLE PVC ETT WITH INTRODUCER

Device Code Device Name Size
DONETRF80 Obturating Introducer for Nasal Endotracheal Tube - Reinforced Flexible 8.0
DONETRF75 Obturating Introducer for Nasal Endotracheal Tube - Reinforced Flexible 7.5
DONETRF70 Obturating Introducer for Nasal Endotracheal Tube - Reinforced Flexible 7.0
DONETRF65 Obturating Introducer for Nasal Endotracheal Tube - Reinforced Flexible 6.5
DONETRF60 Obturating Introducer for Nasal Endotracheal Tube - Reinforced Flexible 6.0
DONETRF55 Obturating Introducer for Nasal Endotracheal Tube - Reinforced Flexible 5.5
DONETRF50 Obturating Introducer for Nasal Endotracheal Tube - Reinforced Flexible 5.0

NASAL (RAE) PVC ETT WITH INTRODUCER

Device Code Device Name Size
DONETRAE80 Obturating Introducer for Nasal Endotracheal Tube - Nasal (RAE) 8.0
DONETRAE75 Obturating Introducer for Nasal Endotracheal Tube - Nasal (RAE) 7.5
DONETRAE70 Obturating Introducer for Nasal Endotracheal Tube - Nasal (RAE) 7.0
DONETRAE65 Obturating Introducer for Nasal Endotracheal Tube - Nasal (RAE) 6.5
DONETRAE60 Obturating Introducer for Nasal Endotracheal Tube - Nasal (RAE) 6.0
DONETRAE55 Obturating Introducer for Nasal Endotracheal Tube - Nasal (RAE) 5.5
DONETRAE50 Obturating Introducer for Nasal Endotracheal Tube - Nasal (RAE) 5.0

Units : Minimum Order Quantity 10 and Multiples thereof